Vista de página 279
A
A-40
Enterprise Operating System Command Line Interface User Manual
Message Error 250: Invalid counter threshold alert name
Description The name specified for the alert is not valid.
Action Specify a counter threshold alert name that has already been created.
Message Error 251: The threshold alert must be disabled
Description The counter threshold alert to be modified/deleted is already
enabled.
Action Disable the threshold alert and then try the command again.
Message Error 253: Cannot Remove a Member Currently Interacting with the
Fabric
Description Current members of the fabric must be included in the Fabric Binding
List.
Action Do not remove active fabric members from the pending Fabric
Binding Membership List.
Message Error 254: A utilization type must be assigned to this threshold alert
Description A utilization type must be set before activating this threshold alert.
Action Add a utilization type and then the threshold alert can be activated.
Message Error 255: Invalid throughput threshold alert name
Description The name of the threshold alert is incorrect.
Action Either the name does not exist, or the new name cannot be used
because it is illegal or a duplicate.