McDATA OPENconnectors Command Line Interace Manual do Utilizador Página 253

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 328
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 252
A
Error Messages
A-13
Message Error 081: Default Zone Enabled
Description The request cannot be completed because the default zone is enabled
Action Disable the default zone and re-submit the command.
Message Error 082: Invalid Interop Mode
Description The value entered for the interoperability mode is not valid.
Action The interoperability mode for the director or switch must be mcdata
(McDATA Fabric 1.0) or open (Open Fabric 1.0). Make the
appropriate changes and re-submit the command.
Message Error 083: Not Allowed in Open Fabric Mode
Description This request cannot be completed while this switch is operating in
Open Fabric 1.0 mode.
Action Configure the interop mode to McDATA Fabric 1.0 mode.
Message Error 088: Invalid Feature Key Length
Description The feature key installed is longer than the maximum length allowed.
Action Be sure that the key has been entered correctly and re-submit. Contact
your sales representative with any further problems.
Message Error 090: Invalid Port Type
Description The port type configured is invalid.
Action A port may be configured to be an eport, gport, or fport. Be sure the
port is configured appropriately and re-submit the command.