McDATA 4416 Switch Module Release Notes Firmware Version 5.2.3.13.00 GUI Version 5.02.3.07 P/N
4
Outstanding Known Issues
15402 Description/Symptom: Cursor remains as hourglass after
firmware activation failure when using Element Manager.
Customer Impact: low
Workaround/Recovery: Disregard the hourglass cursor. The
cursor is still operable. This is a display issue only.
Element
Manager
4416
16033 Description/Symptom: The switch module is not showing the
correct value for Fabric Binding after changing Fabric Binding on
a different McDATA switch in the fabric.
Customer Impact: low
Workaround/Recovery: Refresh the screen.
Embedded
and Element
Manager
4416
16183 Description/Symptom: Domain ID Lock is not activated when
McDATA fabric binding is enabled from another McDATA switch in
the fabric. Fabric binding requires that the specified domain ID
and switch WWN match what is entered into the security list.
Customer Impact: low
Workaround/Recovery: Set Domain ID lock on McDATA 4416
switch. Domain ID lock can be set using the McDATA Embedded
Web Server and selecting Switch>Switch Properties and then
clicking Enable for Domain ID lock and applying changes.
Security 4416
16664 Description/Symptom: An erroneous I/O error message is
displayed while unpacking the firmware image in Maintenance
mode, yet the firmware download and unpack were successful.
Customer Impact: low
Workaround/Recover: Disregard the erroneous message.
Firmware 4416
16701 Description/Symptom: Online loopback test fails when run
against the embedded HBA with the default (256) frame size. The
port can be left in non-functional state.
Customer Impact: low
Workaround/Recovery: Specify a smaller frame size (255).
Non-functional ports can be recovered by resetting the switch
port.
Diagnostics 4416
16743 Description/Symptom: The Event Browser is not displaying new
events.
Customer Impact: Moderate
Workaround/Recovery: Close and reopen the McDATA
Embedded Web Server or McDATA Element Manager. Reopen
the Event Browser.
Embedded
and Element
Manager
4416
Table 1 Outstanding Known Issues (continued)
PR
Number
Description
Problem
Category
Affected
Model
Comentários a estes Manuais